three valve bypass
Hard Water Bypass: How to Build a Plumbed Bypass Around Your Whole House System

A plumbed hard water bypass is a loop built into your plumbing that sends water around your entire whole house water system. It isn’t the same as a tank-mounted bypass valve, which diverts water only at the inlet and outlet of a compatible tank. The three-valve layout uses two tees on the main line. Put one tee before the first piece of treatment equipment and the other after the last so the plumbed hard water bypass can route water around the entire system at once. Once it’s installed and tested, this whole house water system bypass can keep water flowing to the house while the equipment is isolated for startup, maintenance or service. RKIN highly recommends planning a plumbed hard water bypass before installation for compatible systems. Whether you install it yourself or hire a plumber, confirm that the bypass can supply the house with potable water and that the layout suits your system.
A dedicated line to outdoor hose bibs branches off upstream of the water softener and serves those fixtures. For that layout, see Do Outdoor Hose Bibs Need a Bypass from a Water Softener? Full FAQ.
This guide explains the two kinds of bypass, what you or your plumber need to know about your system's connections, and how to build and use a plumbed hard water bypass.
What a Whole House Bypass Is
A bypass gives water two possible routes. In service, water flows from the main line, through your treatment system and on to the house. In bypass, water skips the system and goes straight to the house. Bypassed water is not treated.
There are two common ways to do it:
- A bypass valve on the system. Many whole house control valves and tank heads accept a bypass valve that mounts right at the inlet and outlet. One lever or set of handles switches between service and bypass.
- A plumbed hard water bypass (three-valve bypass). Two tees on the main line and three shutoff valves form a loop around the system: one valve on the line to the system's inlet, one on the line from its outlet, and one on the crossover between the two tees.
A mounted bypass valve isolates the equipment at its connections. A three-valve loop isolates the treatment piping between its inlet and outlet shutoffs, including any hoses or filter housings within that section. Before loosening a fitting or opening a housing, relieve trapped pressure, verify that the isolated section is depressurized and follow the equipment manual’s shutdown instructions.
Why a Bypass Is Worth Building
In its softener operating instructions, the Connected Series manual lists these reasons to bypass the softener.
- Servicing the system.
- A water leak at the system.
- Shock treating the well and piping with chlorine or another disinfectant.
- Running outside lines that don't bypass the system for lawn sprinkling or similar uses.
On a compatible installation, a bypass can keep water flowing to the house while the equipment is isolated for service. If a leak continues after you switch to bypass, shut off the main water supply. During well disinfection, follow your well contractor’s instructions for bypassing equipment and when to resume household water use.
What You or Your Plumber Need to Know Before Installation
Start with your system's connection size and its "What's in the box" list on the product page.
- The 1-inch versions of RKIN’s OnliSoft, OnliSoft Pro and tank-based Whole House Carbon Water Filter, along with the 1-inch salt-based Water Softener and Well Water Filter, include a bypass valve and two 1" MNPT elbows per treatment tank. For other combos, check the box list for the exact model.
- 1.5-inch systems don't include a bypass valve, adapters or 1-inch elbows. The bypass needs to be built into the plumbing, which usually means a three-valve bypass. The 1-inch elbows and fittings aren't compatible with 1.5-inch systems.
- For CBS cartridge systems and other equipment without an included bypass valve, check whether a plumbed bypass suits your equipment and local code. Ask a licensed plumber if you're unsure. For the RKIN Whole Home Reverse Osmosis System, have RKIN and a licensed plumber confirm the bypass design for your installation before using this layout.
A few points from the Connected Series manual also help with planning:
- Raised arrows on the control valve body and the bypass valve show the direction of water flow. Pipe the inlet and outlet in the direction of the arrows.
- If you or your plumber sweat copper pipe, cover the yoke and the bypass valve with wet rags to prevent heat damage, and use lead-free solder and flux. PVC or plastic pipe needs primers and solvent cements recommended for potable water. Match the primer and cement to the pipe type, for example CPVC cement for CPVC pipe and PVC cement for PVC pipe, and follow the cure time on the can before restoring water.
- The manual directs installers to connect lines that don’t need softened water upstream of the softener.
Before you start, check whether local rules allow you to work on the main water line and whether you need a permit or inspection. Obtain any required permit before starting. Call a licensed plumber if local rules require one, if you’re unsure about backflow requirements, or if you’d prefer help cutting into the main line or soldering copper pipe.
How to Build a Plumbed Hard Water Bypass
This is the general sequence, whether you do the work yourself or hire a plumber. Your system's manual and local code come first.
- Shut off the main water supply, open a cold-water faucet to relieve pressure and drain the section you’ll cut. Verify that the shutoff holds and the section is depressurized before cutting.
- Plan the layout. Set the tanks on a level surface. Measure the height of the system's inlet and outlet so the new valves line up with them.
- Cut the main line and add two tees, one upstream for the supply to the system and one downstream for the return to the house.
- Install the bypass valve on the main line between the two tees. This is the crossover valve.
- Install a shutoff valve on each tee branch: an inlet valve on the line to the system and an outlet valve on the line back from it.
- Connect the branches to the system's inlet and outlet, following the flow arrows. If your system includes a bypass valve, it mounts at the system's connections as the manual shows.
- Test the crossover and house-side connections. After the joints have set or cured as directed, keep both treatment shutoffs closed, open the crossover and restore water slowly. Purge air at a cold-water faucet and check the pressurized joints for leaks.
- Test the treatment branches and commission the system. Test all new piping as required by local code. If the required test pressure exceeds the equipment rating, have a licensed plumber isolate the equipment from the test pressure and test the piping. Follow the system manual for filling, purging air, flushing and opening the valves. Check the treatment-side joints for leaks as they come under pressure. Once startup is complete, confirm that both treatment shutoffs are open and the crossover is closed.
- Label the three valves so anyone in the house can switch it later.
Service and Bypass Positions
- Service: inlet and outlet valves open, crossover valve closed. Water runs through the system.
- Bypass: crossover valve open, then close the inlet and outlet valves. Water goes around the system, untreated.
Opening the crossover first keeps water flowing to the house while you isolate the system. The Connected Series manual uses the same order before servicing: first open the valve in the bypass line, then close the valves at the inlet and outlet.
If your system has its own bypass valve, use it the way the manual shows. On the Connected Series control valve, the lever parallel to the inlet and outlet piping is the service position. At a right angle to the piping, it's in bypass. For more on when to switch, see Water Softener Bypass Mode: When and Why to Use It.
Watch a Bypass Being Built
RKIN’s video walks through a plumbed hard water bypass with two tees and three ball valves, from measuring and cutting the pipe to the bypass and in-service valve positions.
Before cutting, follow step 1 to shut off the main water supply, open a cold-water faucet, drain the section and verify that it’s depressurized. For solvent-welded joints, use primer and cement rated for potable water and approved for your specific pipe and fittings. Follow the cement manufacturer’s full cure time before restoring water, then check every new joint for leaks as described in steps 7 and 8. When switching to bypass for service, follow your system manual. For the Connected Series three-valve layout, open the crossover before closing the two treatment shutoffs.
Plan It Before Installation Day
Planning the bypass before installation lets you or your plumber include it in the initial piping layout. Before the install, check your system's connection size and box list, then decide where the tanks will sit. Browse the RKIN whole house water treatment systems to compare setups and what each one includes.
Frequently Asked Questions
Do I need a bypass for a whole house water system?
RKIN highly recommends planning a bypass for compatible systems. It can keep water flowing to the house while the equipment is isolated for service. If a leak continues after switching to bypass, shut off the main water supply. For well disinfection, follow your well contractor’s instructions.
Does my RKIN system come with a bypass valve?
The 1-inch RKIN tank models listed above include a bypass valve and two 1" MNPT elbows per treatment tank. RKIN’s 1.5-inch systems ship without a bypass valve, adapters or 1-inch elbows. If you install a bypass on a 1.5-inch system, it's built into the supply plumbing. Check the box contents for your exact model.
What is the difference between a bypass valve and a three-valve bypass?
A mounted bypass valve switches flow at the equipment’s inlet and outlet. A three-valve bypass uses two tees and three valves to isolate the treatment piping between its two shutoffs. Relieve trapped pressure and verify that the section is depressurized before opening a housing or disconnecting piping.
Is bypassed water treated?
No. In bypass, water goes around the system and reaches the house untreated. Switch back to service when the work is done.
Can I plumb a bypass myself?
Yes, if local rules allow you to do the work and you’re comfortable cutting and joining the main water line. Check permit and inspection requirements before you start, and obtain any required permit. Hire a licensed plumber if local rules require one or if you’re unsure how to cut, join or test the piping safely.





















0 comments